Konverter frekuensi statis output tiga fase
Konverter Daya Seri AC60 adalah catu daya yang mengubah pasokan listrik menjadi tegangan dan frekuensi yang diperlukan melalui sirkuit konversi daya. Karakteristik utama adalah untuk memasok output daya gelombang sinus murni dan stabil, distorsi harmonik rendah, frekuensi stabilitas tinggi dan regulasi. can impersonate many of the world of frequency voltage and output characteristics,and cover the whole industry needs,entirely consistent with the design engineer in research and production and testing of the product testing and life, and a simulated tests to a low, import equipment and Produksi listrik dan aplikasi lainnya. Selain itu, ini juga akan mendukung ruang udara dan peralatan militer 400Hz.
Karakteristik kinerja
1. Have Tegangan Tinggi, Over Current dan Short-Circuit dan Overheat Warning Device
2,16 bit mikroprosesor, kontrol cerdas dan operasi yang mudah
3. Gangguan Distorsi Rendah, Input dan Output benar -benar terisolasi, aman dan dapat diandalkan
4. Unique Transient Wave Membentuk Kontrol Nilai dan Distorsi Rendah, Kontrol Presisi Tinggi
5.Dynamic Quick, saat perubahan beban dalam 0 - 100%, waktu respons stasioner <0,1s
6. Menyediakan tegangan jaringan standar dunia, frekuensi, pengujian simulasi semua jenis produk listrik
7. Tanpa radiasi, bahan harmonik kecil dan perawatan khusus, tanpa mengganggu
8. Tegangan keluaran: tingkat rendah: 0-150 V 、 Tingkat Tinggi: 0-300V Disesuaikan terus menerus
9. Mesin memiliki lebih banyak fungsi, permukaan, dan sumber adalah satu: dengan tegangan output level 0,5 terdekat, arus dan frekuensi dan daya tangan faktor daya
Parameter Teknik:
Model
|
13060
|
13100
|
33150
|
33300
|
331000
|
332000
|
334500
|
336000
|
338000
|
3316000
|
Capacity(KVA)
|
6
|
10
|
15
|
30
|
100
|
200
|
450
|
600
|
800
|
1600
|
Circuit model
|
IGBT/SPWM pulse
width adjustment mode
|
Output
|
50Hz/60Hz 45-65Hz
|
Load stability
|
≤±1%
|
frequency stability
|
fixed-frequency≤±0.01%,frequency modulation≤±0.1%
|
Input voltage
|
220V±10%
|
380V±10%
|
Phase
|
single
phase
|
three
phase four wire
|
Wave distortion
|
≤3%
|
Output voltage
|
1 - 500 V
continuous-tuning
|
Reaction time
|
≤2mS
|
DPI ( dots
per inch )
|
frequency meter
|
0.1Hz
|
Voltage meter
|
0.1V
|
Current meter
|
0. 1A
|
Power meter
|
0.1W
|
Ammeter display
|
Frequency,
voltage, current, power or PF 4 number display
|
Protection function
|
over
voltage, over current, over temperature, over load, short circuit, and automatic
alarm
|
Insulation reactance
|
500Vdc
20MΩ
|
Pressure endurance
insulation
|
1500Vac/5mA/1min
|
Cooling model
|
Compulsive
fan cooling
|
Working temperature
|
-10℃-45℃
|
Relative humidity
|
0-90%(No condensing)
|
Altitude
|
1500meters
|
Dimension (W×L×H)mm
|
660*400*700
|
450*900*900
|
500*1100*1100
|
1320*600*1490
|
850*1450*1880
|
1160*1910*1880
|
1260*2000*2080
|
830*3262*2260
|
model
|
333000
|
3350000
|
33100000
|
Capacity(KVA)
|
3000
|
5000
|
10000
|
Input
|
Voltage
|
400V±15% 3phase 4wires or 3phase 5wires
|
Frequency
|
45-65Hz
|
Power Factor
|
≥0.90
|
Output
|
Voltage
|
3phase 3 wires ,voltage(300-500V/690)can be chosen
|
Frequency
|
50Hz/60Hz can be chosen
|
Frequency Stability
|
≤0.01%(0-100% when load are changing,output frequency are not changing )
|
Load Stability
|
≤3%(100% pure resistance load)
|
Overload Ability
|
110% 1hour ,150% 10minutes
|
Wave Distortion
|
Pure sine wave,THD≤3%
|
Efficiency
|
≥90%(100% loads)
|
Display
|
Input/output voltage/ frequency,3phase phase voltage/current,active power .working time.history error etc.
|
Control mode
|
IGBT/SPWM Pulse width adjustment mode
|
Protection Class
|
IP54
|
Insulation Reactance
|
>2MΩ
|
Pressure endurance Insulation
|
1800Vac/5Ma/1minute
|
Noise Level
|
50dBA @1meter
|
Cooling Model
|
Converter:heat pipe cooling transformer:Compulsive fan cooling
|
Protection Function
|
The output power supply have perfect protection function of over voltage, over current, short circuit, converter overheat . Consider the different control of the ship's electricity load, when the output load capacity reach the set value,will alarm, so as to control the electricity load
|
Environment
|
-10℃~+50℃ and 0~90%
|